SENSITIVE LAYERS FOR OPTICAL SENSORY DEVICES FOR ALUMINUM
DOI:
https://doi.org/10.61841/qc9a0c14Keywords:
sensitive layers, immobilization, solid phase-luminescent determination.Abstract
The possibility and optimal conditions for immobilization by eriochrome blue SE, eriochrome gray SQL on polymeric carriers were studied. The positive effect of immobilization of the investigated oxyazocompounds on their chemical-analytical properties is shown. The optimum conditions for the complexation of the reagents with aluminum are established. New systems of organic carrier reagent for solid-phase luminescent determination of aluminum are proposed.
Downloads
References
1. I.V. Shugaley, A.V. Garabadzhiu, M.A. Ilyushin, A.M. Sudarikov. Some aspects of the influence of aluminum and its compounds on living organisms // Ecological chemistry. T. 21. - No. 3.– 2012.– P.172-186.
2. O.M. Petrukhin, O.O. Maksimenko. Sensors in analytical chemistry. // Ros.chem. g. (J. Ros. Chemical. About. Va. D.I. Mendeleev). - 2008 .-- T. LII. - No. 2. - C.3-7.
3. Zolotov Yu.A., Ivanov V.M., Amelin V.G. Chemical test methods of analysis. M.: URSS editorial, 2002.
4. Cattrall R.V. Chemical sensors. M .: Scientific world. -2000. - from. 144.
5. Smanova Z.A. Monitoring of natural waters using immobilized reagents for the determination of heavy and toxic metals Reports of the Academy of Sciences of the Republic of Uzbekistan. 2011. No. 5, S.58-60.
6. AgnieszkaZuber, Malcolm Purdey, Erik Schartner, Caroline Forbes Benjaminvan der Hoek and etc.
7. Detection of gold nanoparticles with different sizes using absorption and fluorescence based method //
8. Sensors and Actuators B: Chemical. – May 2016. – Vol. 227. – P.117-127.
9. Gavrilenko N. A., Saranchina N. V., Gavrilenko M. A. Solid-phase spectrophotometric determination of selenium (IV) using dithizone immobilized in a polymethacrylate matrix // Analytics and Control. - 2014
.-- T.18. - No. 4. - C.424-429.
10. Romanovskaya G. I. Development of luminescent analysis methods in Russia over twenty years // Zh. analit. chemistry. 2011, Volume 66, No. 11, p. 1157-1163 No. 3, p. 72-76.
11. Ostrovskaya V.M., Zaporozhets O.P. Indicator systems. Moscow: FSUE VTIII 2002.266 p.
12. Otto M. Modern methods of analytical chemistry (in 2 volumes). M .: Technosphere, 2004, 416 p. (v. 1), 288 s. (v. 2).
13. Markhol M. Ion exchangers in analytical chemistry. M.: Mir, 1985, v. 2, 280 p.
14. Myasoedova G.V., Shvoeva O.P., Savvin S.B. Chelating sorbents. The science. Moscow 1984.239 p.
15. Zeltser L.E., Arkhipova A.A., Bychenko A.V. Immobilized 8-hydroxyquinoline as a sensitive sensor layer on aluminum // Zh. analyte. Chemistry. - 1995.-T.50.-No. 7.- S. 725-728.
16. Golovina A.P., Levshin L.V. Chemical luminescent analysis of inorganic substances. - M.: Chemistry, 1978.-245 p.
17. Smanova ZA Immobilization as a way to improve the analytical characteristics of organic reagents Uzb. chemical journal 2009. No4. S.72-76.
18. Zeltser L.E., Vereshchagina N.V., Arkhipova A.A. Improvement of chemical-analytical parameters of some oxyazo compounds as reagents on aluminum during immobilization on some carriers // Dokl. An RUz. -1994.-No. 7.-S. 26-28.
19. Yagov V.V., Zuev B.K., Kovarsky I.I., Kovalenko V.V. Sensor, 2001, No. 2, p. 46-50.
20. Swan N.B., Planck A.B. Rapid test for the detection and semi-quantitative determination of the amount of heavy metals in waters // J. Analytical Chemistry. - 1997. - T.52. - No. 6.- P.643-646.
21. Zaporozhets O.A., Haver O.M., Sukhan V.V. Immobilization of analytical reagents on the surface of carriers // Advances in Chemistry. - 1997. - T.66.- No. 7.
22. 20. Smanova Z.A., Gevorgyan A.M., Mamazhanova G.A. Sorption-photometric determination of aluminum on the surface of a polymer carrier // Uzbek Chemical Journal.-Tashkent, 2010. No. 2.-S.38-41.
23. Reshetov V. Around the World, 2007, No. 4, p. 84-92. M .: Nauka, 1984, 171 p.
24. Brykina G.D., Smirnova I.P. "Optics and spectroscopy." Determination of trace amounts of aluminum in wastewater by solid-phase spectrophotometry. 1991, Vol. 70, issue 4, - 270 s.
25. Carrol M.K., BringtF.V., HiftyeG.M. Fiber-optic fluorescent sensor with a time resolution for simultaneous determination and / or // - 1989. - 61, - 15. P. 1768-1772.
26. Smanova Z.A., Gafurova D.A., Savchkov A.V. 1- (2-pyridyl-azo) -2-oxynaphthalene-3,6-disulfonic sodium immobilized reagent for the determination of iron LC. St. Petersburg, 2011.-No 4.-S.648-651.
27. Smanova ZA Development of sorption-spectroscopic analysis methods using immobilized organic reagents Vestnik NUUz, 2010. No. 3, S.156-161.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation .
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.