SAVING ENERGY IN VENTILATION AND AIR CONDITIONING SYSTEMS

Authors

  • Ismanxodjayeva M.R. Candidate of Technical Science, assistant professor in Tashkent Institute of Architecture and Civil Engineering Author

DOI:

https://doi.org/10.61841/ep1cvw70

Keywords:

saving energy in ventilation and air conditioning systems

Abstract

The peculiarity of microclimate support systems is that they consume a large number of energy resources, including thermal and electric energy and tap water. The problem of reducing energy consumption by ventilation (HV) and air conditioning (SLE) systems, as part of the general problem of efficient energy use, is especially relevant in the highly continental conditions of the Republic of Uzbekistan.A quantitative assessment of the energy efficiency of microclimate facilities is based on the total annual energy consumption of the systems. Annual energy consumption appears to be the most objective energy indicator, since it is in the annual cycle that all energy consumption modes are fully manifested.With SK equipment, the determination of the annual heat or cold consumption of SV or SCR is reduced to the integration of the power consumption of the equipment depending on the season. The latter value is a function of the heat content of the outdoor air, because heat and artificial cold are only used to process the outdoor air. Among the variety of models representing the annual change in the parameters of the outdoor air, we distinguish two groups. The first type of models is based on a description of the annual course of monthly average parameters. Models are presented in tabular form or described analytically. A variation of this model of the external climate is the so-called representative year, the use of which has become widespread abroad.

 

 

Downloads

Download data is not yet available.

References

1. Sizov A.M. Complex-temporal form of representation of the external climate in the calculations of microclimate conditioning systems (SCM). The dissertation for the degree of candidate of technical sciences. - Riga, 1975.

2. Masuch J. Genanigkeit von Energieverbrauchsberechnungen fu..r raumlu.fttechnisches Anlagеn bei reduzierter Wetterdatenmenge // HLH 33. – 1982. – № 11. – Nov.

3. Ananyev V.A., Balueva A.N. et al. “Ventilation and air conditioning system” Practice, educational course, M, Euroclimate; Ed. Arctic 2000.416 s.

4. Robert McDowall, P. Engineering Change Inc. “Fundamentals of HVAC Systems” Ashra E-learning USA 2010

5. Lili Tan and James A. Love “A Literature Review on Heating of Ventilation Air with Large Diameter Earth Tubes in Cold Climates”, Energies, Canada 2013

6. Belova E.M. Air conditioning systems with chillers and fan coils. EUROCLIMATE, 2008

7. Kokorin O.Ya. Domestic equipment for creating ventilation and air conditioning systems. M. “Veza” 2005, 97 p.

8. Bogoslovsky V.N., Kokorin O.Ya., Petrov L.V. “Air conditioning and refrigeration”, M., Stoizdat, 1995.

9. Ananyev V.A. and others. Ventilation and air conditioning systems. Theory and practice. Tutorial. M.Euroclimate, Arina, 2011.216 p.

Downloads

Published

31.10.2020

How to Cite

M.R., I. (2020). SAVING ENERGY IN VENTILATION AND AIR CONDITIONING SYSTEMS. International Journal of Psychosocial Rehabilitation, 24(8), 5314-5320. https://doi.org/10.61841/ep1cvw70