Application of a Robotic Arm in Assisting Disinfection Before Venipuncture Needle Insertion
DOI:
https://doi.org/10.61841/mk9ahd78Keywords:
medical robotics, automatic venipuncture, arm disinfection, blood draw.Abstract
Robots have been widely used in various medical practices ranging from complicated neurosurgery to patient rehabilitation in recent years. They are playing ever more important roles in medical institutions and of great help to medical staff in the jobs they are doing. However, in one of the most frequently performed procedure, venipuncture, application of robots or other automatic devices remains largely unseen. The procedure, though may not be as complicated as a neurosurgery, still requires trained and experienced personnel and is inherently risky. Studies have shown that percutaneous injuries are the most common occupational injuries for medical personnel and the costs are high for medical institutions. Venipuncture consists of several steps. In this paper, the application of a robotic arm in assisting disinfection before needle injection is studied. The ultimate goal is to develop a fully automatic venipuncture system.
Downloads
References
[1] A. Takacs, D.A. Nagy, I.J. Rudas and T. Haidegger, “Origins of Surgical Robotics: From Space to the Operating Room,” Acta Polytechnica Hungarica vol. 13, no. 1, pp. 13–30, 2016.
[2] J. Zhou, X. Ma, Z. Xu and Z. Qi, “Overview of Medical Robot Technology,” Proceedings of the 37th Chinese Control Conference, pp. 5169-5174, July 2018.
[3] T. Haidegger, “Surgical Robots of the Next Decade - New trends and paradigms in the 21th century,” 2017 IEEE 30th Jubilee Neumann Colloquium, pp. 81-82, Nov. 2017.
[4] G. Dwyer, F. Chadebecq, M. T. Amo, C. Bergeles, E. Maneas, V. Pawar, E. V. Poorten, J. Deprest, S. Ourselin, P. D. Coppi, T. Vercauteren, and D. Stoyanov, “A Continuum Robot and Control Interface for Surgical Assist in Fetoscopic Interventions,” IEEE Robotics and Automation Letters, vol. 2, July 2017.
[5] M. Daneshmand, O. Bilici, A. Bolotnikova, and G. Anbarjafari, “Medical robots with potential applications in participatory and opportunistic remote sensing: A review,” Robotics and Autonomous Systems, vol. 95, pp.160-180, Sep. 2017.
[6] J. Ryu, H. Joo and J. Woo, “The Safety Design Concept for Surgical Robot Employing Degree of Autonomy,” 17th International Conference on Control, Automation and Systems,
pp. 1918-1921, Oct. 2017.
[7] X. Wang, S. S. Cheng, and J. P. Desai, “Design, Analysis, and Evaluation of a Remotely Actuated MRI-Compatible Neurosurgical Robot,” IEEE Robotics and Automation Letters, vol. 3, pp. 2144-2151, July, 2018.
[8] A. Namozov, Y. I. Cho, “An Improvement for Medical Image Analysis Using Data Enhancement Techniques in Deep Learning,” International Conference on Information and Communication Technology Robotics, Sep. 2018.
[9] D. Wang, B. Zhang, Lei Zhang, Liqun Zhang, M. Yang, T. Akahoshi, M. Hashizume and M.
G. Fujie, “Efficient multi-parameter calibration method for CVC assist robot with servo- navigation system,” The Journal of Engineering, vol. 2019, iss. 14, pp. 536-542, Feb. 2019.
[10] Z. Li, M. Li, J. Wei, B. Su, C. Pan, S. Kuang, and L. Zhou, “A Robotic System for Investigation on Mis-alignment Force of Needle and Vein,” 2017 2nd Asia-Pacific Conference on Intelligent Robot Systems Needle Insertion into Blood Vessel, pp. 280-283, June 2017.
[11] S. Jindal, W. Singh, and S. Deb, “A Low-cost Smart Vein Viewer System,” 2018 IEEE International Symposium on Smart Electronic Systems, pp. 114-117, Dec. 2018.
[12] World Health Organization, “WHO guidelines on drawing blood: best practices in phlebotomy,” 2010.
[13] E. Bitsika, G. Karlis, N. Iacovidou, M. Georgiou, P. Kontodima, Z. Vardaki, and T. Xanthos, “Comparative analysis of two venipuncture learning methods on nursing students,” Nurse Education Today, vol. 34, pp. 15-18, Mar. 2014.
[14] Y. Murakami, Y. Ohno, M. Nishimura, M. Kido, and K. Yamada, “Evaluating the effectiveness of vascular access imaging device in training of new graduate nurses,” 2014 Health Innovations and Point-of-Care Technologies Conference, pp. 343-346, Oct. 2014.
[15] K. Fukuroku, Y. Narita, Y. Taneda, S. Kobayashi, and A. A. Gayle “Does infrared visualization improve selection of venipuncture sites for indwelling needle at the forearm in second-year nursing students?” Nurse Education in Practice, vol. 18, pp. 1-9, 2016.
[16] J. S. C. Shiao, M. L. McLaws, K. Y. Huang, and Y. L. Guo, “Sharps injuries among hospital support personnel,” The Journal of Hospital Infection, vol. 49, iss. 4, pp. 262- 267, Dec. 2001.
[17] A. Prüss-Üstün, E. Papiti, and Y. Hutin, “Global burden of disease from sharps injuries to healthcare workers,” World Health Report, Geneva Swizerland, World Health Organization 2003.
[18] J. Gabriel, “Reducing needlestick and sharps injuries among healthcare workers,” Nursing Standards, vol. 23, iss. 22, pp. 41-44, Feb. 2009.
[19] J. M. Lee, M. F. Botteman, N. Xanthakos, and L. Nicklasson, “Needlestick injuries in the United States. Epidemiologic, economic, and quality of life issues,” Official Journal of the American Association of Occupational Health Nurses, vol. 53, iss. 3, pp. 117-133, 2005
[20] E. M. O’Malley, R. D. Scott II, J. Gayle, J. Dekutoski, M. Foltzer, T. Lundstrom, et al., “Cost of management of occupational exposures to blood and body fluids,” Infection Control and Hospital Epidemiology, vol. 28, no. 7, pp. 774-782, July 2007.
[21] J. P. Leigh, M. Gillen, P. Franks, S. Sutherland, H. H. Nguyen, K. Steenland, and G. Xing, “Costs of needlestick injuries and subsequent hepatitis and HIV infection,” Current Medical Research and Opinion, vol. 23, iss. 9, pp. 2093-2105, Sep. 2007.
[22] M. L. Balter, A. I. Chen, T. J. Maguire, and M. L. Yarmush, “The System Design and Evaluation of a 7-DOF Image-Guided Venipuncture Robot,” IEEE Trans. on Robotics, vol. 31, no. 4, pp. 1044-1053, Aug. 2015.
[23] A. I. Chen, M. L. Balter, T. J. M., and M. L. Yarmush, “Real-time Needle Steering in Response to Rolling Vein Deformation by a 9-DOF Image-Guided Autonomous Venipuncture Robot,” 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 2633-2638, Sep.-Oct. 2015.
[24] M. L. Balter, A. I. Chen, A. Fromholtz, A. Gorshkov, T. J. Maguire, and M. L. Yarmush, “System Design and Development of a Robotic Device for Automated Venipuncture and Diagnostic Blood Cell Analysis,” 2016 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 514-520, Oct. 2016.
[25] M. L. Balter, A. I. Chen, T. J. Maguire, and M. L. Yarmush, “Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance,” IEEE Trans. on Industrial Electronics, vol. 64, no. 2, pp. 1626-1635, Feb. 2017.
[26] UFACTORY, “uArm pro User Manual,” https://www.ufactory.cc/#/cn/support/download/pro, July 2019.
[27] C. Chen, Y. Ye, and W. Hsu, “Automatic venipuncture insertion point recognition based on machine vision,” Journal of Advances in Technology and Engineering Research, vol. 4, no. 5, pp. 186-190, Oct. 2018.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation .
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.